Breaking Needles Issue
Osman Bayrak
There is a metal bar with a small tab that fits into a small notch at the
top of the hook assembly. There is a small slot immediately behind the notch
where the needle enters. The tab keeps the slot from rotating with the hook.
If the slot has moved, when the needle comes down, it will hit metal and not
enter the hook area. That could cause your needle breaks.
There will be a tiny movement because the tab is slightly smaller than the
notch, but the notch should not be able to move past the tab.
There has to be a gap between the tab and the back of the notch of about the
diameter of a needle. Too little and the thread can't pass between smoothly,
too much and the notch will rotate out of position.
It may be easier to see if you remove the bobbin, needle plate and side
covers. Rotate the main shaft by hand watching as the needle enters the hook
area. Look at the top of the hook assembly as the needle penetrates and
you'll see the slot that I mentioned. Adjust the retainer tab by loosening
the two screws. The center of the tab should line up left and right with the
center of the needle as it penetrates. I use an old needle between the tab
and notch to check the front to back clearance.