Pearl Elite - Troubleshooting

Pearl Elite - Troubleshooting

Dean Armando
If you experience Possible Causes Solution
Leaks
Pretreatment solution dripping from Solenoid Hose may have come loose. Push hose in to quick connect
Excessive pretreatment solution dripping from nozzle Nozzle Cap is loose Tighten Nozzle Cap
Nozzle O-Ring is not installed Install Nozzle O-Ring
Check Valve is not installed Install Check Valve
Pretreatment leaking from back of the unit onto the garment Pump Hoses may have come loose Remove cover panel and push hoses in to quick connects
Pearl Elite not performing as expected
No Power Power switch is in off ( O) position Switch Power to On ( | ) position
Power supply cord is not plugged in to the wall outlet Plug the power supply cord to the wall outlet
Nozzle Cart stops or sputters during movement or spray cycle Belt tension has become too loose Tighten the belt tension by adjusting the motor plate.
Rail not properly lubricated Lubricate the rail with a silicone spray
Nozzle Cart stalls or sputters during homing sequence Nozzle Cart is not actuating the limit switch The limit switch may have been bumped or become misaligned. Realign the limit switch so the Nozzle Cart makes proper connection with the limit switch actuator
Build up of Pretreament solution on bottom pan of Pearl Elite after spray cycle Normal operation Use towels or rags to regularly clean the inside of the unit.
Table area under the Pearl Elite rear becomes excessively messy Pump Hoses may have come loose Remove cover panel and push hoses in to quick connects
Spray pattern not performing as expected
Spray pattern is canted to one side Nozzle is slightly canted Reposition the nozzle so the spray pattern is straight
Spray pattern is heavy on one side and light on the other Nozzle is clogged Try cleaning the nozzle with cleaning solution
Replace the nozzle and O-Ring

Spray pattern is inconsistent and sporadic

 

Pretreatment solution container is low or empty Replace the pretreatment solution and prime the unit again following the “Priming the Pearl PTM” instructions
Spray pattern is not the entire width of the platen Nozzle is clogged Try cleaning the nozzle with cleaning solution
Replace the nozzle and O-Ring

 