Gasket Replacement on the Anajet mPower

customer

This is a guide for replacing the gaskets on an AnaJet MPiv2 Maintenance Station.

Note: Gaskets are only replaced on a clean surface.

 

This applies to Anajet MPiv2 Maintenance Stations only.

 

Supplies

Required supplies:

  1. GAUGE, BRACKET (150992-001) (suggested)
  2. Phillips head screw driver #0
  3. Needle (100746) (for clearing out the drain holes)
  4. Narrow Cleaning Applicator (71-4505).
  5. Wide Cleaning Applicator (71-4504)
  6. Syringe (100747) filled with MOLYKOTE 111 Grease
  7. GPI Garment Printer Cleaning Solution
  8. Lint Free Wipes (150204-001)
  9. SEALING SCREW, 2-56X1/4 PH FL 100? (150889-001) x2 per gasket j. GASKET RETAINER (ana-p-2152) (re-use)
  10. GASKET (ana-p-2151) l. Cleaning Fluid 4oz.(CF-FT125)

 

 

 mPower TDR Gasket Replacement 1

 

Replacement

  1. Release the carriage from the maintenance station.

    Menu -> Maintenance Functions -> Print Carriage Control -> Release Carriage

  2. Clean the maintenance station with cleaning fluid and wide applicators, and then dry the area off with a lint free wipe.

    mPower TDR Gasket Replacement 2

  3. Remove the Philips sealing screws in the gaskets, two per gasket. Then remove the gasket and the gasket retainer.

    mPower TDR Gasket Replacement1 3

  4. Save and clean the Gasket Retainer with Alcohol, this will be used later.
    Remove any O-Rings left in the Gasket Retainer Be sure to remove all ink on the gasket retainer

    mPower TDR Gasket Replacement 4


  5. Clean the Gaskets slots with an alcohol dipped wide applicator.
    Be sure to remove all ink inside the gasket area, leftover ink can lead to a bad seal and poor suction.

    mPower TDR Gasket Replacement1 5


    mPower TDR Gasket Replacement1 6

  6. Apply grease to the gaskets slots and spread evenly across the entire surface with a narrow cleaning applicator.
    Failure cover the entire surface evenly could lead to a bad seal and poor suction.

    mPower TDR Gasket Replacement1 7

  7. Apply grease to the entire back surface of the gasket with a syringe and spread evenly with a narrow cleaning applicator.
    Failure to cover entire surface evenly could lead to a bad seal and poor suction.

    mPower TDR Gasket Replacement1 8  mPower TDR Gasket Replacement1 9  mPower TDR Gasket Replacement1 10

  8. Place the gasket on corresponding slot in the maintenance station.
    Align the drain holes of the gasket to the gasket slot

    mPower TDR Gasket Replacement1 11

  9. Apply grease to the entire back surface of the gasket retainer and spread evenly with a narrow cleaning applicator.
    Failure to cover entire surface evenly could lead to a bad seal and poor suction.

    mPower TDR Gasket Replacement1 12

  10. Place the gasket retainer in the gasket in the corresponding gasket.

    mPower TDR Gasket Replacement1 13

  11. Secure the gaskets with new sealing screws, finger tight, and remove an grease blocking the gasket drain holes with the needle.
    Over tightening sealing screws can break the o-ring and result improper sealing

    mPower TDR Gasket Replacement1 14

 

Verification/Testing

Test with Gauge

  1. With the carriage released, Place the GAUGE, BRCKET on the maintenance station, lining up the pin holes and ensuring the slotted side of the gauge is facing up.

    mPower TDR Gasket Replacement1 15

    mPower TDR Gasket Replacement1 16

  2. Turn on the pump by pressing Menu -> Jobs -> Enter at the same time to access the Technical Support Menu and then going to Module Test -> Maintenance Functions -> Pump On.
     
  3. Push down on the gauge to create a seal and after a few seconds attempt to lightly lift up on the gauge.
     
    • If gauge comes off and the seal is poor, the gasket will have to be cleaned, greased, and secured with new screws. Turn off the pump before repeat steps 5-10 in the replacement section
    • If the maintenance station maintains its seal with the gauge while the pump is on, turn off the pump and attempt of lift up on the gauge. The gauge should maintain its seal for at least a few seconds.
    • If gauge comes off immediately and the seal is poor, the gasket will have to be cleaned, greased, and secured with new screws. Turn off the pump before repeat steps 5-10 in the replacement section
       
  4. Once the test is complete, secure the carriage. Menu -> Maintenance Function -> Print Carriage Control -> Secure Carriage

 

Test without Gauge

  1. With the carriage secured, lines filled, and carts containing ink, perform a 10 second print fill.

    Menu -> Maintenance Function -> Startup Fill -> Fill Print Lines - Fill For 10 Seconds 

    Once complete, release the carriage and see if the maintenance station gaskets are full of ink.

    Menu -> Maintenance Function -> Print Carriage Controls -> Release Carriage

    mPower TDR Gasket Replacement1 17

      1. If the gaskets are full of ink, secure the carriage.

        Menu -> Maintenance Function -> Print Carriage Control -> Secure Carriage
         

        • Perform a light clean before use.

    1. If the gaskets have not filled close to the rim, repeat steps 5-10 in the replacement section

Leave a comment