Holding Counter Reset on the DTG M2 and M4 Garment Printer
customer
Buy parts for the DTG M2 and M4 Garment Printer Here!
-
7.1 Introduction
- If the system is in the operation mode or the setup menu mode, press the [Power] key to turn the power off.
- While holding [Forward] key, [Back] key and [Next] key in the operation panel simultaneously, press [Power] key. The maintenance mode2 will start running and display the maintenance menu.
This chapter provides information on the maintenance mode2. The maintenance mode2 provides the user with functions of displaying and initializing the life counters. It is used in the manufacturing process, adjustment, and maintenance. The maintenance mode2 is implemented in the system firmware. All functions are available from the operation panel.
7.2 Operations in Maintenance Mode2This section explains how to start up and operate the maintenance mode2 as well as provides the list of available diagnosis items.
7.2.1 Starting Up the Maintenance Mode2To use the maintenance mode2, you must first call up the maintenance menu on the operation panel. The maintenance menu is completely independent of the normal operation mode and setup menu display mode. To run the maintenance menu, follow the steps below.
7.3 Maintenance Menu
The maintenance menu includes the following diagnosis items.
7.3.1 Counter Display Menu
This menu displays the life counters. It consists of the following diagnosis items.
7.3.2 Counter Initialization Menu
This menu initializes the life counters. The parameters that can be initialized in this menu are as follows.
7.3.3 Counter Update Menu
This menu updates the life counters. The parameters that can be updated in this menu are as follows.
7.3.4 Counter-Print Menu
This menu prints the life counter values. The parameters that can be updated in this menu are as follows.
7.3.5 Media Feed Menu