BAD CC ENCODER:
- Make sure the machine is configured as an EMC10 using the information in the Operations Manual. Check the Table of contents for the page listing "Configuring the EMC10".
- Check the same information used in the "Off Color Index" section.
- Replace the Color Change Bd., after checking the Color Change Harness connection at the rear of the PCB for a good connection. Check the other end of the cable at the 4 Axis PCB. It is accessible from rear of the machine where the Interface Cable is connected. A "CC COMMAND" error may also be caused if the cable harness isn't connected correctly at either end. The other end of the harness connects to the right side of the 4 Axis PCB as if standing in front of the machine.
- If error still shows, reseat the 4 Axis PCB using the information in the Technical Manual that shows how to replace the PCB.
- If the problem persists, replace the 4 Axis PCB.