EMC 10 X OR Y RACK NOT DONE

Osman Bayrak

X OR Y RACK NOT DONE:

  1. Oil the Pantograph as a first measure, if it hasn't been done lately, refer to the Operation Manual. Lubricating the EMC 10.
  2. Try Reconfiguring. Refer to the Operation Manual under "Configuring the EMC10" in the contents of the manual.
  3. Check all the X and Y Motor cables for damage and the connectors for proper connection, and cleanliness. Electronics stores carry a non-residue spray for cleaning electronic parts. Refer to the Parts Manual for an illustrated description of this Harness Assembly.
  4. Check the Logic 5V for proper setting. See page 1& 2 of this guide.
  5. Reseat the 4 Axis PCB & CPU PCBs using the information in the Technical Manual that shows how to replace these 2 PCBs.
  6. Check all rubber belts connected to X or Y Motor systems for damage. They may also be too loose. See Technical Manual (EMC10) for information on checking proper belt tensions, and replacement.
  7. Check for loose pulleys in the X or Y Axis systems. They could be loose on the shaft(s).
  8. If none of these suggestion correct the problem call your distributor for a service call.